INTRODUCTORY NOTES

Please read carefully before installing, connecting and using the device this user manual. In case of any problems with understanding its content please contact the seller of the device.

Self-assembly and commissioning of the device is possible provided that you use appropriate tools. However, it is recommended to assemble the device by quali-qualified staff.

Due to the possibility of damage to the access control handle:
- the device should not be installed in doors with a door closer,
- the door in which the device will be installed must be properly installed and adjusted along the door frame,
- the door leaf must close easily (not spring) and with maximum operating forces acting on the device must not exceed the thresholds specified in the device specification tion contained in this manual,
Door handles with access control should not be installed in saunas, cold rooms and other rooms, conditions in which the relative humidity and ambient temperature exceed the threshold specified specified in the technical specifications of the device.

For increased safety, it is recommended to install a recessed patent insert ELB -01,-02, -03H4 , which will also act as an additional emergency entry option.

The manufacturer is not responsible for damage that may result from incorrect installation or operation and from making independent repairs and modifications.

Remember to:
- use the device in accordance with its intended purpose, keep it away from moisture and fire,
- do not throw into fire, do not hit, crush or expose the device to damage
mechanical,
- do not clean the device with water, solvents or other chemicals,
- clean the device housing only when the power source is cut off for cleaning
you can use a damp cloth, but after using it you should wait until it is completely dry
casing drying out,
- do not make any modifications or repairs yourself

Attention!
Devices with an penetration coefficient higher than or equal to IP44 can be mounted outdoors (e.g. bell buttons, external video intercom cassettes, cameras, etc.). Information about the penetration coefficient is included in the technical specifications of the device.

1. GENERAL CHARACTERISTICS AND PURPOSE

An electronic door handle with access control easily limits access to protected rooms by unauthorized persons. It is intended for both left and right doors, and the universal mounting screw spacing of 40-45 mm allows in most cases to use a mortise lock already installed in the door.

There is a proximity key reader (Mifare 13.56 MHz) and a touch numeric keyboard on the handle body.
After bringing the key fob closer to the reader and entering the correct PIN code, the lock inside the lock is released.

1. GENERAL CHARACTERISTICS AND PURPOSE

An electronic door handle with access control easily limits access to protected rooms by unauthorized persons. It is intended for both left and right doors, and the universal mounting screw spacing of 40-45 mm allows in most cases to use a mortise lock already installed in the door.

There is a proximity key reader (Mifare 13.56 MHz) and a touch numeric keyboard on the handle body.
After bringing the key fob closer to the reader and entering the correct PIN code, the lock inside the lock is released.

2. SET CONTENTS
Electronic door handles, two anti-slip pads, two keys, instructions, hole marking template

Two pins for door handles, a pin retainer, a set of fasteners
Depending on the thickness of the door leaf, select the appropriate fittings - pin, bushings and tension screws

Fig. 1


3. CONSTRUCTION

Battery compartment | Touchpad, backlit keyboards
Fig. 2


Fig. 3


4. PRINCIPLE OF OPERATION

After giving an impulse from the electronic access control module, the servomotor unlocks the mechanical transmission, thus enabling the door to be opened by pressing the handle on the external part normally. The opening is signaled by a sound. The waiting period for pressing the handle is factory set to approximately 5 seconds, after which the gear is locked again and the lock switches to the waiting state for another impulse from the electronic access control module.

From the inside (of the premises), it is always possible to open the door by simply pressing the handle. After closing the open door, the latch mechanism is immediately activated, making it impossible to open the door from the outside without an impulse from the electronic access control module.

It is possible to open the lock in an emergency using a regular mechanical key, 2 of which are included in the set.
Additionally, the device has an access lock function, which allows only the administrator's code or emergency entrance key to enter the room.


INSTALLATION OF THE ELECTRONIC DOOR HANDLE

The set includes pins, sleeves and screws enabling the installation of handles in doors with a thickness of 35 ~ 65 mm. During assembly, select the appropriate length of the attached elements.

Attention!
Installation should be carried out with emergency keys, which may be necessary in the event of slamming a door with an unprogrammed lock. The lock should be installed on an open door leaf. After completing the installation and programming of the lock, a device operation test should be performed, also on the open door leaf.

Example of locks installed in standard doors:

Fig. 4


Example of locks installed in aluminum profile doors:
Fig. 5


5.1. SETTING THE HANDLE ORIENTATION (LEFT/RIGHT DOOR)

All electronic handles are universal and can be attached to both left- and right-opening doors

5.1.1 ORIENTATION SETTING - FRONT OF THE HANDLE

In order to determine the opening direction of the handle with built-in access control, unscrew the fastening screw located on the inside of the plate (Fig. 6), then change the direction of its position and then screw it back using the fastening screw.


Fig. 6

5.1.2 ORIENTATION SETTING - BACK OF THE SIGN

To set the opening direction of the handle with a built-in battery compartment, unscrew the mounting screw located on the inside of the plate (Fig. 7), then change its direction and then screw it back in using the mounting screw.


Fig. 7


5.2. INSTALLATION OF THE PIN IN THE ELECTRONIC HANDLE

The pin should be placed in the socket located in the device body marked with a triangle, and then install the locking pin included in the accessory set.

Attention:
When installing the pin, remember that the socket located in the lock body was directed towards the handle
                                                                                                                                                                                                                    Fig. 8
                                                                                                                                                    

PREPARING A REPLACEMENT SHAFT

If you want to use a different pin than the one included in the set, proceed as follows:
get an 8 x 8 mm pin, then measure the appropriate length and cut the pin.

Note: The pin must be cut to an appropriate length to eliminate the possibility of moving this element during use, otherwise the pin socket will be at risk of damage.


5.3 BATTERY INSTALLATION

To install the battery in the battery compartment, slide the battery compartment cover upwards.

Fig. 9

Attention!
- For proper operation of the device, the use of alkaline batteries is required, do not use rechargeable batteries.
- It is recommended that the handle be installed and programmed with the door leaf open; after checking the correct operation, the door leaf can be closed.
- After inserting the batteries for the first time, the handle automatically goes into the armed state, so remember to insert the batteries after installing the electronic handle in the door leaf. If the batteries have been inserted earlier, in order to open the door, you must use the emergency key, which is recommended to have with you during the installation.

The electromechanical door handle is powered by 4 DC 1.5 V AA alkaline batteries and can operate for approximately 1 year on one set of batteries.


5.4. ASSEMBLY DIAGRAM

To install an electronic door handle, proceed as follows:
Fig. 10

To install an electronic handle in the door existing mounting holes can be used or prepare new ones according to the attached template
to the set. To avoid damaging the mortise lock it should be dismantled and make sure that it complies with the ny with one of the sample standards shown in Fig.4 or Fig.5.

ATTENTION! It is also possible to install a door handle in a different standard after prior verification that installation in such a lock will not cause damage lock and electronic handle. Additionally, the insert must be removed from the lock tympanic. In most cases, the hole after demolition the installed drum insert will serve us well as an assembly track for the lower sleeve of the sign.

Electronic handle assembly sequence:
Fig. 11
1. According to Fig. 11, install the rubber washer and screw the mounting sleeves (the set includes two types of sleeves that should be selected according to the door thickness) to the front handle body.

2. Install the pin in the handle socket and lock it with a cotter pin (the set includes two types of pins that should be selected according to the door thickness).

ATTENTION!
When installing the cotter pin in the pin, remember that the triangle symbol on the pin socket faces towards the handle of the handle. After placing the pin, adjust it to fit into the previously prepared hole in the pin socket.


Fig. 12
a. put the outer part together with the connecting sleeves through the door leaf with the previously installed lock
b. run the connecting cables coming from the outer part of the sign above the mortise lock,

Fig. 13
c. put a rubber washer on the back of the sign/handle,

Fig. 14
d. connect the wires connecting both sides of the handle (the connection socket is located under the battery compartment cover),
e. remove the battery compartment cover, then screw the back part of the sign together with the front part using black tightening screws
f. insert 4 1.5 V AA alkaline batteries into the power compartment,

Fig. 15

g. close the battery compartment,
h. program the electronic door handle.


5.5 EMERGENCY OPENING METHOD

Fig. 16

If you need to enter the premises, use the emergency key to insert the emergency key into the insert located at the bottom of the device on the access control side and turn the key to the right until you feel resistance. Then, by pressing the handle, you can enter the room.

Attention !
It is possible to provide emergency power to the handle in the event of a discharged battery. For this purpose, use the USB C socket (DC 5 V) located at the bottom of the external handle.

6. PROGRAMMING AND OPERATING THE ELECTRONIC HANDLE WITH ACCESS CONTROL

6.1. ADMIN CODE

When logging into the programming mode for the first time, we must enter the administrator code.
For this purpose:
- wake up the device's keyboard by touching it,
- enter * + #
- assign a 6-digit administrator code + #
- repeat the 6-digit administrator code + #,
- after correctly registering the administrator password, the device will provide the administrator number -
tora and will redirect us to the settings panel.
* - cancel, undo, exit and delete.
# - confirm, exit


6.1.1. SETTINGS

6.2. MODES PROGRAMMING

How to set Passage Mode (lock always in "unlocked" state, no need for verification):
1. Press the sequence "0" + "#" + admin password + "#".
2. After successfully completing this operation, you will receive a confirmation message.
3. Door Mode has been activated, which means that the lock will be unlocked after using the user's proximity code or key until the user enters the user's proximity code or key again.
4. To deactivate the transition mode, repeat the sequence from step one.


6.3 SETTING THE AUTOMATIC UNLOCK TIME

To change the automatic locking time (you can choose the locking time: 5S, 10S, 15S, 20S):
1. To set Auto Lock for 5 seconds, press "1" + "#" + admin password + "#".
2. To set Auto Lock for 10 seconds, press "2" + "#" + admin password + "#".
3. To set Auto Lock for 15 seconds, press "3" + "#" + admin password + "#".
4. To set Auto Lock for 20 seconds, press "4" + "#" + admin password + "#".
After performing the appropriate operation, the lock will be automatically blocked after the selected time.


7. UNLOCKING AND LOCKING THE LOCK

Unlocking the lock: In order to enter the protected room using the electronic door handle, activate the urad code lock, then enter the 6-digit user code and confirm it with #.

Blocking the lock: entering an incorrect code 5 times or applying an unprogrammed proximity key will result in blocking the lock for approximately 90 seconds.


ATTENTION
When the battery level is low, the door handle will activate an alarm signal (single siren sound) and will generate the message "Low power please change battery!


8. RESET BUTTON

There is a handle reset button under the battery cover. To perform a reset, press the reset button for 6 seconds. The reset will be confirmed with a command.
After performing the reset procedure, the lock data was restored to factory settings.

Fig. 17

Eura-Tech Sp. z o. o. hereby declares that the type of radio device - electronic door handle with access control ELH-71H4 - is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.eura-tech.eu




EURA-TECH Sp. z o.o.
ul. Przemysłowa 35A, 84-200 Wejherowo, Poland
www.eura-tech.eu
All rights reserved.
The pictures, drawings and texts used in this manual are the property of ‘EURA-TECH’ Sp. z o.o. Reproduction, distribution and publication
of the whole or parts of the manual without the author's consent are prohibited!
The Eura-Tech Sp. z o.o. company reserves the right to change technical parameters and modify the operating instructions without notification.
At the same time, we would like to inform that the most up-to-date version of the manual can be found on the website www.eura-tech.eu
on the subpage of the given product.
The EU declaration of conformity of the given device is provided on the http://www.eura-tech.eu website