Сode panel AC -20C7, -30C7
Sort:
Search:
INTRODUCTION
Before connecting and using the devices, please read this manual carefully. In case of any problems with understanding its content, please contact the seller of the device. Self-assembly and commissioning of the device is possible provided that the installer has basic knowledge in the field of electrical engineering and the use of appropriate tools. Nevertheless, it is recommended that the device be installed by qualified personnel. The importer is not responsible for any damage that may result from improper installation or operation of the device, as well as from performing independent repairs and modifications.
1. INTENDED USE AND GENERAL CHARACTERISTICS
The AC-20C7 and AC-30C7 code locks are devices intended for use in security systems. The devices have two relay outputs that can control the inputs to the property. For example, an electromagnetic bolt that opens a wicket or an entrance door can be connected to the exit. All lock functions are programmed using the numeric keypad. After programming the device, it is possible to later control the entrance to the property in 3 ways:
- entry only by means of ID proximity card,
- entry with the use of a combination of: proximity card and 4-digit access code,
- entry by means of proximity card or 4-digit access code.
2. CONTENTS OF THE KIT
The complete set includes:
- combination lock,
- mounting screws,
- installation key.
The external structure of combination locks is shown in Fig. 1-2.
Fig. 1. Construction of the AC-20C7 code lock
Fig. 2. Construction of the AC-30C7 code lock
The code lock is equipped with two relay outputs for controlling the electromagnetic bolt. It is possible to connect the standard bolts to the system using the "NO" and "COM" contacts, as well as the reversible bolts - using the "NC" and "COM" contacts.
4. INSTALLATION OF THE LOCK AND CONNECTION DIAGRAM
The AC-20C7 and AC-30C7 locks are designed for surface mounting. In order to install the lock at the entrance to the property, proceed as follows: 1. Separate the lock mounting base from its main body by first unscrewing the mounting bolt at the bottom of the
lock using a special key (kit accessory). Then, the rear part of the casing should be slightly moved a few mm upwards in relation to the front part, then tilted by about 20 degrees and removed (Fig. 3).
Fig. 3. Sliding off the rear part of the housing
2. In the wall or pillar where the lock is to be installed, mark 4 places for dowels and mounting screws, using for this purpose 4 external holes in the lock mounting base (see fig. 4 - 5).
Fig. 4. Installation of the AC-20C7 code lock
Fig. 5. Installation of the AC-30C7 code lock
3. Drill holes in the marked places and then place 4 mounting pins in them.
4. Connect the electric cables from the power supply and electromagnetic lock (and possibly from
other devices) to the lock connection socket - according to the diagram shown in Fig. 6.
Fig. 6. Connection diagram of AC-20C7 and AC-30C7 code locks
(!) Attention:The cable harness must pass through the large circular opening in the center of the base fastening
5. Use 4 mounting screws to fix the lock base to the wall.
6. Put the lock body on the base fixed to the wall and screw the fastening screw at the bottom of the lock with the key.
Diagram notes:
- All elements shown in the diagram (electromagnetic bolts, bell, power supply, closing button, etc.) - are elements of additional equipment.
- The diode D1 (accessories of the set) should be connected with the electromagnetic boltonly and exclusively in the case of powering the bolt with direct current.
- Insulate any unused terminals in the wiring harness.
1 | Power |
Red | 12-16V DC or AC power supply (any polarity) |
2 | Power |
Black | mass |
3 | Door opening sensor |
Brown | connection of the door open sensor |
4 | Normally Open Button 1 |
Grey | connection of the normally open button 1 lowering property |
5 | Normally Open Button 2 |
Orange | connection of the normally open button 2 lowering property |
6 | GND |
Pink
| mass |
7 | NO1 |
Green
| relay 1 normally open contact |
8 | COM1 |
Violet
| common contact of relay 1 |
9 | NC1 |
Blue
| relay 1 normally closed contact |
10 | NO2 |
Green & White | relay normally open contact 2 |
11 | COM2 |
Violet & White | common contact of relay 2 |
12 | NC2 |
Blue & White | relay normally closed contact 2 |
13 | BELL |
Yellow
| connection of the bell |
14 | GND |
White
| mass |
15 | Ground |
Ground
| Ground
|
5. HOW TO USE A CODE LOCK
The device is equipped with two relay outputs, enabling the operation of two partitions, and an
output for connecting a bell.
Characteristic:
a) I ZONE
• Service by 1000 users,
• Three ways to activate the lock:
- entering the property only with an authorized ID proximity card,
- entering the property with an authorized ID proximity card or digital access code,
- entering the property with an authorized ID proximity card and digital access code.
• Operation by 10 users,
c) Possibility to connect a bell (see fig. 6).
5.1. ENTRY TO THE PREMISES
Activating the entrance to the property depends on the set method of lock activation (see section 5.1.).
In order to enter the property with the use of a proximity card, the proximity card must be pulled in front of the reader. If the card is correct, the zone opening indicator will turn green (zone 1) or red (zone 2) and you will hear a short double acoustic signal. If an incorrect card has been inserted - a series of four short beeps will appear.
To enter the property with a proximity card or code, slide the proximity card in front of the reader / enter the code. If the card / code is correct, the zone opening indicator will light up in vgreen (zone 1) or red (zone 2) and a short double acoustic signal will be emitted. If an incorrect card / code has been entered - a series of four short beeps will appear.
To enter the property with a proximity card and code you should:
a) First, swipe the proximity card in front of the reader (if the card is correct, a short double acoustic signal will be emitted, if an incorrect card has been entered - a series of four short beeps will appear) and enter the code. If the code is correct - the zone opening indicator will turn green (zone 1) or red (zone 2) and a short double acoustic signal will be emitted. If an incorrect code has been entered - a series of four short beeps will appear.
b) First, enter the code (if the code is correct, a short double acoustic signal will appear, if the code has been incorrectly entered - a series of four short beeps will appear) and then draw any proximity card in front of the reader. The zone opening indicator will turn green (zone 1) or red (zone 2) and a short double beep will sound.
5.2. SIGNALING OF THE ZONE OPENING INDICATOR
The zone opening indicator informs the user about the zone in which the bolt has been released.
Fig.7
A. When the zone 1 lock is released, the zone open indicator turns green
B. When the zone 2 lock is released, the zone open indicator turns red
5.3. ADDITIONAL FUNCTIONS
5.3.1. LOAD BUTTON
The normally open button can be connected to both zones 1 and 2. Details of the connection can be found
in the diagram in Fig. 6 (page 8).
5.3.2. DOOR CLOSING DETECTION
The device has a door closure detection function - after opening and closing the door, the device blocks the bolt, even if the slowing time is set to a longer one. The connection details can be found on the diagram in Fig. 6 (page 8).
5.3.3. RINGER FUNCTION
The device has an output for connecting a chime. Connection details and parameters can be found on the diagram in Fig. 6 (page 8). To trigger the bell, press the button *.
5.4. ENTERING THE SETTING MODE
5.4.1. ENTERING THE SETTING MODE BY MEANS OF THE MASTER CODE
To enter the settings mode, enter the master code twice. The default master code is1234. The lock status indicator will turn red and a long beep will sound to confirm that the mode has changed successfully. To exit the settings menu, press #.
5.4.2. ENTERING THE SETTING MODE VIA THE MASTER CARD
To enter the setting mode with the master card, the master card must be swiped, the operating status indicator will turn red and a long acoustic signal will be emitted. Pulling the master card again results in exiting the settings mode, which is signaled by the working status indicator lighting up in green and by the appearance of two short acoustic signals.
5.5. POTENTIAL CODE PROBLEMS
5.5.1. LOSS OF MASTER CODE
In case of loss of the master code, disconnect the device from the power supply and press #. Then reconnect the power source and after a few short signals the password will be reset to the default -1234.
5.5.2. ENTERING WRONG CODES
If the wrong code is entered three times or the wrong card is withdrawn, a long acoustic signal will appear and the device will be blocked for 60 seconds.
5.5.3. GENERAL NOTES REGARDING CODES
The user code must be different from the master code. The codes in zone one must be different from those in zone two.
6. PROGRAMMING THE LOCK
6.1. PROGRAMMING THE LOCK ACTIVATION METHOD
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed.
Then, to enter the lock activation mode programming mode, press * and0, the lock operation status indicator will start flashing red. Then enter the appropriate code from the table below:
00 | Access by means of an ID proximity card only |
01 | Access by means of a proximity ID card or digital access code |
02 | Access by means of a proximity ID card and digital access code |
If after entering the appropriate code the indicator lights up red again and a long acoustic signal is emitted from the loudspeaker - the settings have been saved successfully. To exit the settings menu, press #.
6.2. CHANGE OF MASTER CODE
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to change the master code, press the * and buttons3 (Operation status indicator flashes red), then enter a new 4-character code twice. The appearance of a short and long signal confirms the correct change of settings.
To exit the settings menu, press #.
6.3. SETTING THE LENGTH OF THE MASTER CODE
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to enter the master code length programming mode, press * and9, the lock operation status indicator will start flashing red. Then press0and4 (a single, short acoustic signal will appear, the lock operation status indicator will light up in red) and enter a digit corresponding to the number of digits of the desired code (pressing the digit 2 will set the code with a length of two characters, etc.). The appearance of a single, short acoustic signal means that the settings have been changed correctly. The appearance of a series of three short acoustic signals means that the desired code length is identical to the previously set one.
To exit the settings menu, press #.
CAUTION
Changing the length of the master code automatically deletes all the stored cards and codes from the lock's memory.
6.4. ADDING MASTER CARDS
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed.
Then, to add a master card for zone 1, press the buttons*and7.If the work status indicator:
- starts blinking green - no master card has been saved in the lock memory, you can proceed to the next step,
The next step is to add a new card - swipe the desired card in front of the reader until a long acoustic signal appears and the lock status indicator lights up red - the card has been added.
To exit the settings menu, press #.
6.5. ADDING USER CARDS AND CODES FOR ZONE 1
6.5.1. ADDING CARD + USER CODE FOR ZONE 1
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to add a new user for zone 1, enter any number in the range000-999,the zone open indicator will turn green and the operation status indicator will flash red.
CAUTION
If the zone opening indicator turns red and the operating status indicator starts flashing, go red - the number you have dialed is already in use. Pressing the * button twice will delete the code saved under the given number. After the zone opening indicator lights up green (confirming deletion of the old code), you can add a new code.
Then, swipe the card (a long beep will appear and the working status indicator will start blinking red) and enter a new code (with the same length as the master code length). A long acoustic sound and the red light of the operating status indicator mean that the settings have been saved successfully. The above steps must be repeated for each new user.
To exit the settings menu, press#.
6.5.2. ADDING A USER CODE FOR A ZONE 1
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to add a new user code for zone 1 you must first press the * and buttons9 (the operation status indicator blinks red), then buttons0and2 (a short acoustic signal will sound and the operating status indicator will turn red). The next step is to enter the desired user number in the range 000-999 (a double short beep will appear) and entering the code to be set - the code length must be the same as the length of the master code. Successful saving of the settings will be confirmed
with a long beep.
To exit the settings menu, press #.
CAUTION
If the selected user number had a code assigned earlier - the device will behave identically and the new setting will replace the previous one.
6.5.3. GROUP ADDING OF USER CARDS FOR ZONE 1
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to add user codes for partition 1 as a group, you should first press the * and buttons9 (the operation status indicator will flash red), and on then buttons0and1 (a short acoustic signal will be emitted and the operating status indicator will turn red). The next step is to enter the first user number in interval000-999 (a long single beep will appear) *, followed by a number corresponding to the total number of cards that we want to enter (e.g. 050 means entering cards for 50 more users) *. After the appearance of a short single acoustic signal, swipe the cards in front of the reader one at
a time - after adding each card, a short beep will appear first, and then a long one).
To exit the settings menu, press #.
* remember to keep the 3 positions of the code - if the number is less than one hundred, it should be
preceded with a zero (for numbers 10-99) or two zeros (for numbers 0-9)
6.6. ADDING USER CARDS AND CODES FOR ZONE 2
6.6.1. ADDING CARD + USER CODE FOR ZONE 2
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. To add a new user for partition 2, first press buttons * and4 (the operation status indicator will flash red), and then dial a number between 00-09,the zone open indicator will turn green.
CAUTION
If the zone opening indicator turns red - the dialed number is already in use. Pressing the * button twice will delete the code saved under the given number. After the zone opening indicator lights up green (confirming deletion of the old code), you can add a new code.
Then, swipe the card (a short and long acoustic signal will appear) and enter a new code (of the same length as the length of the master code). A long acoustic sound, the zone opening indicator goes out and the operating status indicator turns red means that the settings have been saved successfully. The above steps must be repeated for each new user.
To exit the settings menu, press #.
6.6.2. ADDING A USER CODE FOR ZONE 2
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. To add a new user code for zone 2, first press buttons * and9 (the operation status indicator will flash red), then the buttons0 and3 (a short acoustic signal will be emitted, the operating status indicator will turn red).
The next step is to enter the desired user number in the range00-09 (a short double acoustic signal will appear) and entering the code to be set - the code length must be the same as the master code length. The appearance of a short and long acoustic signal confirms the successful setting of the code.
To exit the settings menu, press #.
CAUTION
If the selected user number had previously been assigned a code - the new setting will replace the previous one. If the selected user number had previously assigned a code and proximity card - the new code will replace the previous one, the card will remain unchanged.
6.7. DELETING CARDS AND CODES
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will sound to confirm that the change has been made mode. Then, to delete cards / codes, first press the * and buttons8 (sta- red flashing), and then press the button twice8.The appearance of a long acoustic signal indicates that the cards and codes have been successfully removed.
To exit the settings menu, press #.
6.8. CHANGING THE RELEASE TIME OF THE LOCK
6.8.1. CHANGING THE LOCK RELEASE TIME FOR ZONE 1
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to change the bolt release time for zone 1, press buttons * and1 (the operation status indicator will flash red), then enter two digits from the range00-99corresponding to the desired bolt release time (e.g. entering 04 means setting the bolt release time to 4 seconds, etc.). If the operating status indicator turns red and a long single beep sounds, set up have been successfully saved. When selecting the setting00–it is necessary to either move the card or enter the code to open and close the gate.
To exit the settings menu, press #.
6.8.2. CHANGING THE LOCK RELEASE TIME FOR ZONE 2
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming the they think to change the mode. Then, to change the deceleration time, press the * and buttons5 (the operating status indicator will flash red), then enter the two digits of z compartment00-99corresponding to the desired bolt release time (e.g. entering 04 means setting the bolt release time to 4 seconds, etc.). If the operating status indicator turns red and a single long beep sounds, the settings have been changed. When selecting the setting00 -it is necessary to either move the card or enter the code to open and close the gate.
To exit the settings menu, press #.
6.9. SETTING OF THE ANTI-SABOTAGE FUNCTION
The built-in loudspeaker will generate a continuous acoustic signal for 60 seconds when high light intensity is detected by the photo-optical sensor. Detection can be stopped by entering the master code.
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to disable the anti-tampering function, press the * and buttons6 (indicator working status starts flashing red), then press the buttons0and1.A long acoustic signal and a red light of the operating status indicator will indicate that the alarm has been successfully triggered.
To enable the anti-tampering function, press the * and buttons6 (work status indicator flashing red), and then press the buttons0and2. The appearance of a long acoustic signal and a continuous yellow illumination of the operation status indicator will indicate a successful
deactivation of the alarm.
To exit the settings menu, press #.
6.10. RESTORING FACTORY SETTINGS
To enter the settings mode, enter the master code twice. The lock status indicator will turn red and a long acoustic signal will be heard confirming that the mode has been changed. Then, to restore the device to factory settings, you need to first press the * and buttons8 (the operating status indicator will start blinking red), and then press the 9 button twice. A long beep indicates that the device has been successfully restored to the factory settings.
To exit the settings menu, press #.
7. SUMMARY TABLE OF CODES
Full text of the EU declaration of conformity is available under the following web address: www.eura-tech.eu
EURA-TECH Sp. z o.o.
ul. Przemysłowa 35A, 84-200 Wejherowo, Poland
www.eura-tech.eu
All rights reserved.
The pictures, drawings and texts used in this manual are the property of ‘EURA-TECH’ Sp. z o.o.
Reproduction, distribution and publication
of the whole or parts of the manual without the author's consent are prohibited!
The Eura-Tech Sp. z o.o. company reserves the right to change technical parameters and modify the operating instructions without notification.
At the same time, we would like to inform that the most up-to-date version of the manual can be found on the website www.eura-tech.eu
on the subpage of the given product.
The EU declaration of conformity of the given device is provided on the http://www.eura-tech.eu website